Triton ULTRA connects to exacqVision through direct TCP events or a Triton Cloud connection with camera mapping and bookmarks. Staff can receive configured notifications, activate recording actions, and find footage associated with sensor detections.
A sensor inside a restroom can be linked to a camera covering the entrance, giving staff context around the location of an alert. ULTRA’s live occupancy view adds information from inside the room to help responders assess conditions before entering.
.png)
Direct connection from Triton ULTRA
How it works: Configure a TCP Listener under Serial Ports in exacqVision. Serial Profile keywords match the event messages sent by ULTRA, and Event Linking uses those keywords to activate the configured response.
Camera actions: Associate the event with the cameras covering that location and choose actions such as Record or Notification. The keywords must match the sensor’s event messages for the rules to run.
Triton Cloud + exacqVision
Connect the systems: Authenticate to the exacqVision server using its public IP address or domain, port, protocol, credentials, and server name. The server must be reachable from Triton Cloud.
Camera association: Map each sensor to the camera you want bookmarked and save the configuration. The Cloud connection creates events and bookmarks for reviewing detections with the mapped camera.
View occupancy alongside camera footage
Add ULTRA’s RTSP occupancy visualization separately to exacqVision for live viewing alongside camera feeds. Staff can check room activity between alerts as well as when responding to a detection.
Before you start: Use the guide for your connection method and confirm server access and camera associations. For the Cloud setup, run a test for a mapped sensor and verify the event and bookmark in exacqVision.
Frequently Asked Questions
How do the direct and Cloud options differ?
Direct TCP messages activate exacqVision Event Linking actions. Triton Cloud authenticates to the server and uses saved camera mappings to create events and bookmarks.
What does the Cloud connection require?
A Triton Cloud account and a licensed exacqVision server reachable from Triton Cloud, plus its connection details and credentials.
Can occupancy be viewed between alerts?
Add ULTRA’s RTSP visualization separately to view room activity alongside camera feeds.
How do we verify the Cloud setup?
Save a sensor-to-camera mapping, use Run Test in Triton Cloud, and confirm the event and associated camera in exacqVision.
Resources
ExacqVision – Triton ULTRA Integration Guide — full setup guide for the on-prem TCP listener path.
exacqVision – Triton Cloud Integration Guide: authentication, camera mapping, bookmarks, and testing.
Compare Triton ULTRA integration options across video management, access control, intercoms, and staff alerts.